Evaluation of testing face-mask filter samples with LAMP shows high rates of detection in pulmonary TB
T. Kodama, Kazuaki Chikamatsu, Keisuke Kamada, Kazue Mizuno, Y. Morishige, Y. Igarashi, Asami Osugi, A. Aono, et al. (13 authors)
The International Journal of Tuberculosis and Lung Disease · 2024-09
Abstract
(MTB) in bioaerosols derived from patients with active pulmonary TB is a potential alternative diagnostic method for patients with presumed TB who cannot expectorate sputum.</sec><sec><title>OBJECTIVE</title>To assess the efficacy of a bioaerosol particle collection method to capture MTB and diagnose TB.</sec><sec><title>METHODS</title>A mask-like filter holder (3D mask) with a water-soluble gelatine filter (GF) and one containing a water-insoluble polypropylene filter (PPF) were prepared. Eligible patients wore the 3D mask with GF or PPF within 3 days of starting anti-TB drugs. The GF and PPF filters were collected after 2 and 8 h. DNA was extracted from the filter samples and tested using loop-mediated isothermal amplification (LAMP).</sec><sec><title>RESULTS</title>Filter samples were collected from 57 and 20 patients with and without active pulmonary TB, respectively. The GF and PPF sensitivity was 76.2% and 83.3%, respectively. The specificity of both methods was 100%. Of the 57 patients diagnosed with non-expectorated sputum samples, including suction phlegm, gastric lavage, and bronchial lavage fluid, 55.6% and 50.0% were positive by GF and PPF, respectively.</sec><sec><title>CONCLUSION</title>We present a 3D mask filter sampling method for exhaled bioaerosol particles that can be used in clinical practice to diagnose patients with presumed TB.</sec>.
MeSH terms
- Medicine
- Sputum
- Lipoarabinomannan
- Nuclear medicine