Factors influencing false-positive results of rifampicin resistance detected by Xpert MTB/RIF: A retrospective study in Zhejiang, China
Guihua Wu, Jing Wang, Xiaoqun Xu, Hui Wei, Long Cai, Libin Liu
Heliyon · 2024-05
Abstract
Objective: This study aimed to explore the factors influencing false-positive results for rifampicin resistance (RIF-R) detected using Xpert MTB/RIF (Xpert). Methods: This retrospective analysis included the clinical data of patients from September 2019 to February 2023. The chi-square and rank sum tests were used to compare differences in patient characteristics between the true-positive and false-positive groups. Logistic regression was used to analyze the factors influencing false positives in the detection of RIF-R by Xpert. Results: < 0.001) probe delays were associated with false positives in Xpert detection of RIF-R. When very low quantification is accompanied by a probe delay, the probability of false-positive RIF-R detection can reach 80 %. Conclusions: Clinicians should consider factors such as probe mutation type, probe delay, and very low quantification accompanied by probe delay when interpreting Xpert results, which can reduce the misdiagnosis of tuberculosis drug resistance.
MeSH terms
- Medicine
- False positive paradox
- Logistic regression
- Retrospective cohort study
- Internal medicine
- Tuberculosis
- False positive rate
- Drug resistance