TB Research

Patient-reported usability and satisfaction with electronic medication event reminder and monitor device for tuberculosis: a multicentre, randomised controlled trial

Tsegahun Manyazewal, Yimtubezinash Woldeamanuel, Tewodros Getinet, Alison T. Hoover, Kidist Bobosha, Oumer Fuad, Belete Getahun, Abebaw Fekadu, et al. (10 authors)

EClinicalMedicine · 2023-01

Abstract

Background: The success of a tuberculosis digital adherence technology relies on patients' satisfaction with and the usability of the technology. This study aimed to evaluate treatment satisfaction and usability of a digital medication event reminder and monitor (MERM) device for patients with tuberculosis to address the prespecified secondary endpoint of the SELFTB trial. Methods: In this multicenter, randomised controlled trial, adults (≥18 years) with new or previously treated, bacteriologically-confirmed, drug-sensitive pulmonary tuberculosis who were eligible to start anti-tuberculosis therapy were recruited from 10 healthcare facilities in Ethiopia. With a computer-generated random number sequence, participants were randomly assigned 1:1 to receive a 15-day tuberculosis medication supply dispensed with an evriMED500® MERM device to self-administer and return every 15 days or the standard in-person DOT. Both arms were followed throughout the standard two-month intensive treatment phase. Treatment was based on the WHO-recommended two-month fixed-dose-combination of first-line anti-tuberculosis drug delivered as a single daily dose (2RHZE). Treatment Satisfaction Questionnaire for Medication version 4 (TSQM 1.4©) was used to measure and compare treatment satisfaction between arms. Adapted System Usability Scale (SUS) was used to assess the usability of the device, with emphasis on ease of use, challenges, benefits, motivation, popularity, and recommendation. The findings were correlated with adherence and clinical endpoints including sputum smear conversion and IsoScreen urine isoniazid test results. This trial is registered with ClinicalTrials.gov, NCT04216420. Findings: ). Interpretation: Our findings suggested that treatment satisfaction scores were superior in the intervention vs control arms and across the domains of Effectiveness, Convenience, and Global Satisfaction. There was excellent usability of the MERM device and a significantly higher number of users likely to promote the device. High tuberculosis burden countries may transform patient-centered care through ongoing evaluation and scale-up of digital health innovations. Funding: U.S. National Institute of Health (NIH) Fogarty International Center and National Institute of Allergy and Infectious Diseases (D43 TW009127) and the Emory Center for AIDS Research (P30 AI050409).

MeSH terms

  • Medicine
  • Usability
  • Tuberculosis
  • Adverse effect
  • Randomized controlled trial
  • Patient satisfaction
  • Sputum
  • Directly Observed Therapy
  • Clinical trial
  • Physical therapy
  • Internal medicine