TB Research

Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children

Pathariya Promsena, Watsamon Jantarabenjakul, Piyarat Suntarattiwong, Tavitiya Sudjaritruk, Suvaporn Anugulruengkitt, Suwatchareeporn Rotcheewaphan, Suthidee Petsong, Panadda Sawangsinth, et al. (12 authors)

Journal of the Pediatric Infectious Diseases Society · 2021-09

Abstract

BACKGROUND: Diagnosing tuberculosis (TB) in children is challenging due to its paucibacillary nature. Loop-mediated isothermal amplification (TB-LAMP) is a simple, rapid, and specific point-of-care molecular diagnostic test. However, evaluation of its performance remains limited in children. This study aimed to evaluate the diagnostic performance of Eiken TB-LAMP among children with presumed tuberculosis disease. METHODS: Pulmonary and extrapulmonary specimens were collected from children under 18 years with presumed TB. Each specimen was tested by using TB-LAMP, acid-fast bacilli (AFB) smear microscopy, and one of the two molecular assays (polymerase chain reaction [PCR] or Xpert MTB/RIF). Sensitivity and specificity were estimated compared to mycobacterial culture as reference standard. RESULTS: From January 2020 to January 2021, 75 participants with presumed TB were enrolled with median age of 7 years (IQR 2-12). Seventeen specimens from 16 (21.3%) children had bacteriologically confirmed TB: 10 pulmonary and 7 extrapulmonary specimens. Overall sensitivity and specificity of TB-LAMP was 76.5% (95% CI 50.1%-93.2%) and 100% (95% CI 94.3%-100%), respectively. It had significantly higher sensitivity than AFB (52.9%, 95% CI 27.8%-77.0%) and similar to other molecular assays; PCR 82.4% (95% CI 56.6%-96.2%), Xpert MTB/RIF 70.0% (95% CI 34.8%-93.3%). Sensitivity of TB-LAMP for pulmonary, lymph node tissue, and extrapulmonary fluid was 80% (95% CI 44.4%-97.5%), 100% (95% CI 39.8-100), and 33.3% (95% CI 0.8-90.6), respectively. TB-LAMP detected all smear-positive (N = 9) and 50% of smear-negative (N = 8) specimens. CONCLUSIONS: TB-LAMP had higher sensitivity than AFB microscopy and accuracy similar to other molecular assays in both pulmonary and extrapulmonary specimens. These findings support using TB-LAMP as a point-of-care test in children.

MeSH terms

  • Medicine
  • Loop-mediated isothermal amplification
  • Tuberculosis
  • Extrapulmonary tuberculosis
  • Internal medicine
  • Mycobacterium tuberculosis
  • Gastroenterology
  • Polymerase chain reaction
  • Pathology