TB Research

Outbreak of Nontuberculous Mycobacteria Joint Prosthesis Infections, Oregon, USA, 2010-2016

Buser GL, Laidler MR, Cassidy PM, Moulton-Meissner H, Beldavs ZG, Cieslak PR

Emerging infectious diseases · 2019-05

Abstract

We investigated a cluster of Mycobacterium fortuitum and M. goodii prosthetic joint surgical site infections occurring during 2010-2014. Cases were defined as culture-positive nontuberculous mycobacteria surgical site infections that had occurred within 1 year of joint replacement surgery performed on or after October 1, 2010. We identified 9 cases by case finding, chart review, interviews, surgical observations, matched case-control study, pulsed-field gel electrophoresis of isolates, and environmental investigation; 6 cases were diagnosed >90 days after surgery. Cases were associated with a surgical instrument vendor representative being in the operating room during surgery; other potential sources were ruled out. A tenth case occurred during 2016. This cluster of infections associated with a vendor reinforces that all personnel entering the operating suite should follow infection control guidelines; samples for mycobacterial culture should be collected early; and postoperative surveillance for <90 days can miss surgical site infections caused by slow-growing organisms requiring specialized cultures, like mycobacteria.

MeSH terms

  • Humans
  • Arthritis, Infectious
  • Cross Infection
  • Prosthesis-Related Infections
  • Surgical Wound Infection
  • Case-Control Studies
  • Joint Prosthesis
  • Environmental Microbiology
  • Disease Outbreaks
  • History, 21st Century
  • Aged
  • Middle Aged
  • Oregon
  • Female
  • Male
  • Molecular Typing
  • Mycobacterium Infections, Nontuberculous
  • Nontuberculous Mycobacteria